Maintenance Methods for Half-Masks, Full-Masks, and Filter Cartridges
I. Storage and Maintenance
Before use, inspect all parts of the mask for damage and replace any damaged parts.
Regularly check the filter cartridge and replace it when necessary.
Incorrect storage can shorten the life of respiratory protective equipment and reduce its effectiveness. Therefore, store the equipment in a clean plastic bag, in a personal toolbox or designated area, in a well-ventilated, clean, and dry environment.
II. Cleaning and Maintenance
Cleaning Instructions
Clean with soapy water or neutral detergent, avoiding organic or corrosive solvents.
Thoroughly rinse the mask in clean water, paying special attention to remove all soap residue from the exhalation valve to prevent corrosion. If possible, use tap water to repeatedly flush the exhalation valve.
Air dry the mask or dry it with a non-lint cloth. Accelerate drying with warm air below 40°C. Do not use an oven to dry, as it may cause aging of rubber components.
Maintenance
Conduct a routine inspection of the product monthly to check for scratches, dents, holes, cracks, notches, or deformation due to aging, heat, or contamination on the mask skirt, sealing area, headband, exhalation valve, and inhalation valve. Replace or contact the supplier for repair if any of these conditions are found.
III. Reference Standards
| Country | Standard Number | Standard Name |
|---|---|---|
| China | GB 2626-2019 | Respiratory Protection - Self-Powered Air-Purifying Particle Respirators |
| GB 2890-2009 | Respiratory Protection - Self-Powered Air-Purifying Chemical Respirators | |
| GB/T 18664-2002 | Selection, Use, and Maintenance of Respiratory Protective Products | |
| GB/T 16556-2007 | Self-Contained Open-Circuit Air Breathing Apparatus | |
| GA 124-2013 | Positive Pressure Fire Fighting Air Breathing Apparatus (Chinese Public Safety Standard) | |
| USA | NIOSH 42CFR84 | General Requirements for Respiratory Protective Equipment |
| ANSI Z88.10 2010 | Fit Testing Methods for Respiratory Protective Equipment | |
| Europe | EN 136-1998(2004) | Respiratory Protective Equipment - Full-Face Masks - Requirements, Testing, and Marking |
| EN 14387-2004 | Respiratory Protective Equipment - Gas Filters and Combined Filters - Requirements, Testing, and Marking | |
| EN 140-1999 | Respiratory Protective Equipment - Half-Masks and Quarter-Masks - Requirements, Testing, and Marking | |
| EN 143-2000 | Respiratory Protective Equipment - Particle Filters - Requirements, Testing, and Marking | |
| EN 149:2001+A1-2009 | Respiratory Protective Equipment - Particle Protection Filters for Half-Masks, Full-Masks, and Filter Cartridges - Maintenance Methods |